Put the same handheld meter into two glasses and it may give you the same number even when different salts are dissolved in them. That limitation matters when you use a TDS reading to judge a kitchen reverse-osmosis system.

Use paired readings on one scale. The example does not establish an acceptance limit.

What the meter senses

Water conducts electricity partly because of the ions dissolved in it. A common TDS meter measures conductivity, then estimates total dissolved solids using a conversion factor. Its display cannot identify individual substances or tell you whether the water is safe to drink.

The instrument becomes more informative in pairs. Suppose the feed reads 300 and the RO outlet reads 30 on the same meter and scale. The reading has fallen by 270, or 90 per cent of the starting value. That percentage describes this pair of samples.

What changed since last time?

If the supply reading rises, a higher outlet reading may still represent a similar reduction. If the feed stays much the same and the outlet climbs over repeated checks, the system warrants a closer look. Take samples at comparable points and under similar operating conditions, following the system’s instructions.

For a question about a named contaminant, write its name down before choosing a test. A targeted water analysis and the system’s certified claims address that question. Another decimal place on a TDS display cannot.